meets your visualization needs.






Efficient. Consistent. Safe.
Setup, teardown, reprocessing — reduced to three steps.
Reusable visualization is 78 IFU steps across setup, teardown, and sterilization. Pristine reduces that to three.
Why it matters: the next case starts on time because nobody is dealing with equipment issues.
Brand-new means a fresh image, every single case.
A reusable scope degrades every time it’s used due to wear and tear, and reprocessing. Pristine is always new; your first case and your 50th both use a brand new, sterile, 4K scope.
Why it matters: the surgeon gets the same 4K clarity every case, every day.
Between every single case
Reprocessing steps
1. Point-of-Use Pre-Cleaning
- Wipe the exterior surface immediately after the procedure.
- Flush internal channels with an enzymatic detergent solution.
- Prevent organic debris and blood from drying.
- Transport the device in a closed container to decontamination.
2. Manual Cleaning
- Submerge the instrument in a recommended enzymatic detergent.
- Brush all internal channels and ports thoroughly.
- Wipe exterior surfaces with a soft, non-abrasive cloth.
- Flush all channels to loosen and evacuate bioburden.
- Actively inspect the scope under proper lighting for residual debris.
3. Sterilization or High-Level Disinfection
- Select the modality based on the device material properties.
- Submerge the scope in chemical disinfectant if performing HLD.
- Utilize an Automated Endoscope Reprocessor (AER) if available.
- Execute low-temperature sterilization (e.g. gas plasma) for rigid scopes.
- Adhere strictly to the required chemical exposure times and temperatures.
4. Rinsing and Drying
- Rinse the device thoroughly with treated or sterile water.
- Remove all chemical residues from internal and external surfaces.
- Purge all internal channels with pressure-regulated compressed air.
- Dry the external body completely with a lint-free cloth.
- Prevent remaining moisture from acting as a microbial reservoir.
5. Storage and Documentation
- Log the serial number and cycle data for complete traceability.
- Store rigid arthroscopes in sterile, designated protective cassettes.
- Keep the instruments in a clean, dust-free environment.
New case. New scope.
Pristine is always brand new.
Sterile and ready — contamination and reprocessing risk, eliminated.
Because every Pristine scope is brand new and 100% sterile, there is no biofilm or bioburden carried from a prior case. That removes the single largest infection vector in the operating room.
Why it matters: the safety question is answered before the case even begins.
Reusable scopes are prone to biofilm and debris.
- 71%of reprocessed endoscopes may be contaminated
- 100%higher rates of infection from endoscopies than expected
- 70%of bacterial infections in the US are caused by biofilms
More healthcare-associated infections are related to contaminated scopes than any other medical device.
